1 . Enter the Access Control module .
2 . On the navigation bar on the left, enter Advanced Function
→
More Pa-
rameters .
3 . Select an access control device in the device list and click M1 Card En-
cryption to enter the M1 Card Encryption page .
4 . Set the switch to on to enable the M1 card encryption function .
5 . Set the sector ID .
NOTE
The sector ID ranges from 1 to 100.
By default, Sector 13 is encrypted. It is recommended to encrypt sector 13.
6 . Click Save to save the settings .
Set RS-485 Parameters
You can set the access control device's RS-485 parameters including the
baud rate, data bit, the stop bit, parity type, flow control type, communication
mode, work mode, and connection mode .
Steps
NOTE
The RS-485 Settings should be supported by the device.
1 . Enter the Access Control module .
2 . On the navigation bar on the left, enter Advanced Function
→
More Pa-
rameters .
3 . Select an access control device in the device list and click RS-485 to en-
ter the RS-485 Settings page .
4 . Select the serial port number from the drop-down list to set the RS-485
parameters .
5 . Set the baud rate, data bit, the stop bit, parity type, communication mode,
working mode, and connection mode in the drop-down list .
NOTE
When the connection mode is Connect Access Control Device, you can
select Card No. or Person ID as the output type.
6 . Click Save .
• The configured parameters will be applied to the device automatically .
• When you change the working mode or connection mode, the device will
reboot automatically .
Set Wiegand Parameters
You can set the access control device's Wiegand channel and the commu-
nication mode . After setting the Wiegand parameters, the device can connect
to Wiegand card reader via Wiegand communication .
Steps
NOTE
This function should be supported by the device.
1 . Enter the Access Control module .
2 . On the navigation bar on the left, enter Advanced Function
→
More Pa-
rameters .
3 . Select an access control device in the device list and click Wiegand to en-
ter the Wiegand Settings page .
4 . Set the switch to on to enable the Wiegand function for the device .
5 . Select the Wiegand channel No . and the communication mode from the
drop-down list .
NOTE
If you set Communication Direction as Sending, you are required to set
the Wiegand Mode as Wiegand 26 or Wiegand 34.
6 . Check Enable Wiegand to enable the Wiegand function .
7 . Click Save .
• The configured parameters will be applied to the device automatically .
• After changing the communication direction, the device will reboot auto-
matically .
7.7. CONFIGURE LINKAGE ACTIONS
FOR ACCESS CONTROL
You can configure different linkage actions for the event detected by the
access control device . After that, linkage actions will be triggered once the
event happens . This mechanism is used for notifying the security personnel
the event or triggering automatic access control in real time .
Two types of linkage actions are supported:
• Client Actions: When the event is detected, it will trigger the actions on the
client, such as the client making an audible warning .
• Device Actions: When the event is detected, it will trigger the actions of a
specific device, such as buzzing of a card reader and, opening/closing of
a door .
7.7.1. Configure Client Actions for Access Event
Even if you are far away from an access point, you can still know what hap-
pens and how urgent the event is by configuring linked actions of access event
on the client . You will be notified on the client once an event is triggered, so
that you can respond to the event instantly . You can also configure client ac-
tions of access points in a batch at a time .
Steps
NOTE
The linkage actions here refer to the linkage of the client software's
own actions such as audible warning, etc.
1 . Click Event Management
→
Access Control Event .
The added access control devices will display in the device list .
2 . Select a resource (including device, alarm input, door/elevator, and card
reader) from the device list .
The event types which the selected resource supports will display .
3 . Select the event(s) and click Edit Priority to define the priority for the
event(s), which can be used to filter events in the Event Center .
4 . Set the linkage actions of the event .