20
21
Fi
g
u
re 4
-2
. D
evi
c
e W
ir
in
g
NOTE
You should set the face recognition terminal’s Wiegand direction to
“Input” to connect to a Wiegand card reader. If connects to an access
controller, you should set the Wiegand direction to “Output” to transmit
authentication information to the access controller.
For details about Wiegand direction settings, see Setting Wiegand
Parameters in Communication Settings.
The power supply for the device should be 12 V DC, 2 A. The suggested
external power supply for door lock is 12 V, 1 A. The suggested external
power supply for the Wiegand card reader is 12 V, 1A.
The suggested power cable’s diameter: 22 AWG. The suggested other
cable’s diameter: 26 AWG.
Do not wire the device to the electric supply directly.
WARNING
The face recognition terminal shall adapt an external listed Class 2
power supply with surge protected function.
4.3. WIRE SECURE DOOR CONTROL UNIT
You can connect the terminal with the secure door control unit .
The wiring diagram is as follows .
Figure 4-3. Secure Door Control Unit Wiring
NOTE
The secure door control unit should connect to an external power
supply separately. The suggested external power supply is 12 V, 0.5 A.
4.4. WIRE FIRE MODULE
4.4.1. Wiring Diagram of Door Open When Powering Off
Lock Type: Anode Lock, Magnetic Lock, and Electric Bolt (NO)
Security Type: Door Open When Powering Off
Scenario: Installed in Fire Engine Access
Type 1
NOTE
The fire system controls the power supply of the access control system.