67
Operation
Parameter listing
Menu
Submenu
Parameter Name
Description
Range
Factory
settings
26..32.
4
System Setting
26..32.
4.
0
Thermoregulation
0 = OFF 1 = ON
0 - 1
0
26..32.
4.
1
External temperature correction T7
WRW&
0
26..32.
4.
2
Boost time
0 - 60 min
0
26..32.
4.
3
Plant frost protection
0 = OFF 1 = ON
0 - 1
0
26..32.
4.
4
T Gradient
&
5
26..32.
4.
5
System Pump Overrun
0 - 255 min
5
26..32.
4.
6
6\VWHPWDQNVRODULQWHJUDWLRQ
$EVHQW 3UHVHQW
0 - 1
0
26..32.
4.
7
CH/DHW shifting priority time
0
26..32. 5
Domestic Hot Water
26..32. 5.
0
DHW Setpoint Temperature
&
65
26..32. 5.
1
Comfort Function
'LVDEOHG
1 = Time Based
2 = Always Active
0 - 2
0
26..32. 5.
2
System DHW Mode
0 = CH Only
'+:7DQN17&
'+:7DQN7KHUPRVWDW
0 - 2
0
26..32. 5.
3
Boiler DHW Mode
0 = CH Only
'+:7DQN17&
'+:7DQN7KHUPRVWDW
0 - 2
0
26..32. 5.
4
Anti-legionella Function
0 = OFF
1 = ON
0 - 1
0
26..32. 5.
5
Boiler DHW Charging Type
0 = Recharging
1 = Full charging
2 = Full charging Legio
0 - 2
0
26..32. 5.
6
System DHW Charging Type
0 = Recharging
1 = Full charging
2 = Full charging Legio
0 - 2
0
26..32. 5.
7
Boiler DHW Circulating Pump Release
0 = Release
1 = Time Programs
2 = Circ Pump special Time Programs
0 - 2
0
26..32. 5.
8
System DHW Circulating Pump Release
0 = Release
1 = Time Programs
2 = Circ Pump special Time Programs
0 - 2
0