65
Operation
Parameter listing
Menu
Submenu
Parameter Name
Description
Range
Factory
settings
25. 0.
5
Max Turnover Level
0 - 100%
75
25. 0.
6
Maximum Water temp
&
95
25. 0.
7
&+GLႇHUHQWLDOWHPSHUDWXUH
&
0
25. 0.
8
CH/DHW shifting priority time
0 - 65535min.
0
25. 1
System Settings
25. 1.
0
Thermoregulation
0 = OFF
1 = ON
0 - 1
1
25. 1.
1
External temperature correction
&
0
25. 1.
2
Boost Time
0 -60min.
0
25. 1.
3
Plant frost protection
0 = OFF
1 = ON
0 - 1
0
25. 1.
4
T Gradient
&
5
25. 1.
5
System Pump Overrun
0 - 255min.
5
25. 1.
6
System pump activation logic
0 = Always active
1 = Heating only
0 - 1
0
25. 1.
7
6\VWHPWDQNVRODULQWHJUDWLRQ
$EVHQW
1 = Present
0 - 1
0
25. 2
Domestic Hot Water
25. 2.
0
DHW Setpoint Temperature
&
65
25. 2.
1
Comfort Function
'LVDEOHG
1 = Time Based
2 = Always Active
0 - 2
0
25. 2.
2
System DHW Mode
0 = CH Only
'+:7DQN17&
'+:7DQN7KHUPRVWDW
0 - 2
0
25. 2.
3
Anti-legionella Function
0 = OFF
1 = ON
0 - 1
0
25. 2.
4
System DHW charge mode
0 = Charge
1 = Full charge
2 = Full charge Legio
0 - 2
0
25. 2.
5
System DHW Circulating Pump Release
0 = Release
1 = Time Program
2 = Special Time Program
0 - 2
0
25. 2.
6
System DHW Charging Priority
$EVROXWH
1 = Shifting
2 = None
0 - 2
0