57
Operation
Parameter listing
Menu
Submenu
Parameter Name
Description
Range
Factory
settings
4.
2.
2
Slope
LT: From 0.2 - 1.0
HT: From 1.0 - 3.5
0.6LT
1.3HT
Increase setting:
,QFUHDVHVWKHÀRZ
temperature, especially at low
outside temperatures.
Reduce setting:
5HGXFHVWKHÀRZWHPSHUDWXUH
especially at low outside
temperatures.
flow
temperature
low
temperature
level
high
temperature
level
outdoor temperature
room temperature
setpoint
°C
°C
23
23
21
21
19
19
30
20
10
0
40
50
60
70
80
90
°C
5
10
15
20
25
3.5
3.0
2.5
2.0
1.8
1.5
1.3
0.8
1.0
0.6
0.4
0
-5
-10
-15
-20
-25 °C
0.8
0.6
1.0
0.4
0.2
4.
2.
3
2ႇVHW
2ႇVHWKHDWLQJOLQHDGMXVWDEOHSHU&
/7)URP&WR&
+7)URP&WR&
0
0
4.
2.
4
5RRPLQÀXHQFHSURSRUWLRQDO
2QO\YLVLEOHRQWKHERLOHULIDURRPVHQVRU
is connected
LT=2
HT=4
4.
2.
5
Max T
Zone 1 Maximum Flow Temperature
/7)URP&WR&
+7)URP&WR&
&
&
4.
2.
6
Min T
Zone 1 minimum Flow Temperature
/7)URP&WR&
+7)URP&WR&
&
&
4.
2.
7
Thermo regulation logic
0 = OFF, 1 = ON
0 - 1
0
4.
2.
8
4XLFNQLJKWVHWEDFN
0 = OFF, 1 = ON
0 - 1
0
4.
2.
9
Heat request mode
0 = Standard
1 = RT Time Programs Exclusion
2 = Forcing Heat Demand
0 - 2
0
4.
3
Zone1 Diagnostics
4.
3.
4
Heat Request Z1
0 = OFF, 1 = ON
4.
3.
9
Heating rate
0 = OFF, 1 = ON
5
=RQH3DUDPHWHUVVHH=RQHFKDSWHU
6
=RQH3DUDPHWHUVVHH=RQHFKDSWHU
20.
%XႇHU
20.
0.
&RQ¿JXUDWLRQ
20.
0.
0
%XႇHU$FWLYDWLRQ
0 = UIT, 1 = AAN
0 - 1
0
20.
0.
1
%XႇHUFKDUJHPRGH
1RWGH¿QHG
1 = Partial charge
2 = Full charge
0 - 2
0
20.
0.
2
%XႇHUK\VWHUHVLV
%XႇHUK\VWHUHVLV
&&
5
20.
0.
3
%XႇHUKHDWLQJ&RPIRUWVHWSRLQW
temperature
%XႇHUKHDWLQJ&RPIRUWVHWSRLQW
temperature
&&
40