89
Maintenance
Maintenance details
The ignition electrode
The ignition electrode (1) is a
FRQVXPDEOHSDUWDQGPXVWEHFKHFNHG
Checking the air pressure
GLႇHUHQWLDOVZLWFKVLGH
6ZLWFKRႇWKHERLOHU
-
Disconnect the silicon hose on
the + side (P1) of the air pressure
GLႇHUHQWLDOVZLWFK
DQQXDOO\7KHHOHFWURGHPXVWEH
renewed, if damages or any wear and
tear is detected. The value of ignition
HOHFWURGHUHVLVWDQFHFDQEHGHWHFWHG
through measurements.
The maximum electrode resistance at
room temperature should not exceed
ȍ
,WFDQEHUHSODFHGXQVFUHZLQJLWIURP
the heat exchanger. Remove and
UHSODFHWKHRULQJ0DNHVXUHRIWKH
tightness of the connection.
In case electrode damage is detected,
verify the status and eventually replace
WKHIXVHDORQJHOHFWURGHFDEOH
In order to ensure continued good
DQGVDIHRSHUDWLRQRIWKHERLOHU
LJQLWLRQHOHFWURGHVKRXOGEHUHSODFHG
every 2 years.
The detection electrode.
The detection electrode (2) is a
FRQVXPDEOHSDUWDQGPXVWEHFKHFNHG
DQQXDOO\7KHHOHFWURGHPXVWEH
renewed, if damages or any wear and
WHDULVGHWHFWHGEXWFHUWDLQO\HYHU\
years. Furthermore, the value of the
LRQL]DWLRQFXUUHQWFDQEHGHWHFWHG
through measurements. Under full load
operations, the minimum ionization
FXUUHQWPXVWDPRXQWWRȝ$
,WFDQEHUHSODFHGXQVFUHZLQJLWIURP
the heat exchanger. Remove and
UHSODFHWKHRULQJ0DNHVXUHRIWKH
tightness of the connection.
Sight glass
If the sight glass (3) is damaged, it can
EHUHSODFHGXQVFUHZLQJLWIURPWKH
heat exchanger. Remove and replace
WKHJDVNHW0DNHVXUHWKHJDVNHWLVLQ
correct position and the connection of
new glass is tight.
$VVHPEO\LVGRQHLQUHYHUVHRUGHU
2
1
3
P
1
(+)
P
2
(-)
(+)
1
3
2
4
5
6
7DNHDODUJHSODVWLFV\ULQJHRU
EHOORZVDQGFRQQHFWD7SLHFHZLWK
a hose connected (2).
-
Connect the + side of the air-
SUHVVXUHGLႇHUHQWLDOVZLWFKWRRQH
end of the T piece with a hose (3).
-
On the other end of the T piece,
connect the + side of a pressure
gauge (4).
7XUQRQWKHERLOHU
3XVKWKHV\ULQJHRUEHOORZVLQYHU\
VORZO\XQWLOWKHERLOHUJRHVLQWR
failure mode (5).
0DNHDQRWHRIWKHSUHVVXUH
LQGLFDWHGE\WKHSUHVVXUHJDXJH
at that point. A switch pressure of
EHWZHHQDQGPEDULV¿QH
A lower or higher switch pressure
LQGLFDWHVDSUREOHPZLWKWKHDLU
SUHVVXUHGLႇHUHQWLDOVZLWFK
$IWHUWDNLQJDPHDVXUHPHQWGHWDFK
the silicon hose from the T piece on
the + side and reconnect the hose
that was previously removed.
CAUTION:
Please note: The + side (P1) is the rear
connector nipple of the air pressure
GLႇHUHQWLDOVZLWFKZLWKRXWUHGFDS
- Remove any soiling from all
connection points for hoses and the
DLUSUHVVXUHGLႇHUHQWLDOVZLWFK
&KHFNWKHFRQGLWLRQDQGWLJKWQHVV
of the hoses of the air pressure
GLႇHUHQWLDOVZLWFK5HSODFHWKH