56
Operation
Parameter listing
Menu
Submenu
Parameter Name
Description
Range
Factory
settings
0
NETWORK
0.
2
BUS Network
0.
2.
0
1HWZRUN3UHVHQFH
Indication of devices connected via BUS
Boiler
Remote Modem
OpenTherm Gateway
1
0.
4
User interface
0.
4.
0
=RQHWREHVHWE\GLVSOD\
1 - 3
1
0.
4.
1
%DFNOLJKWWLPLQJ
1 min - 24 hours
10
min
0.
4.
3
Time Program service type
Select the time program service type
DFFRUGLQJWR(EXVGHYLFHVSUHVHQWLQ\RXU
QHWZRUN
0 = Time programs
1 = Extended time
programs
0
0.
4.
4
Reset System Interfce
OK = Yes, BACK = No
4
Zone1 Parameters
4.
0
Setpoint
4.
0.
0
T Day
Room temperature set point for day period
&
20
4.
0.
1
T Night
Room temperature set point for night
period
&
15
4.
0.
2
T set Z1
Temperature setpoint zone 1
(
/LPLWHGE\3DUDDQG3DUD
)
40
&&
20
&&
75
20
4.
0.
3
Zone frost temperature
&
5
4.
1
Summer/Winter Changeover
4.
1.
0
S/W function activation
0 = OFF, 1 = ON (only active when outside
WHPSHUDWXUHLQÀXHQFH
0 - 1
0
4.
1.
1
S/W temperature threshold
&
15
4.
1.
2
S/W delay time
7LPHEHIRUH6:FKDQJHRYHUEHFRPHV
active
0 - 300 (min)
30
4.
2
Zone1 Settings
4.
2.
0
Zone temperature range
0 = Low Temp (LT)
1 = High Temp (HT)
0 - 1
1
4.
2.
1
Thermoregulation
0 = Fix Flow T
1 = Basi Thermoreg
2 = Room T Only
3 = Outdoor T Only
4 = Room+Outdoor T
0 - 4
0