3 Function description and connections
The present document is a description of the electrical gate control system DRICO
slife
FU12 of
ASO. It contains the installation, operation, maintenance, repair, shutdown and disposal of the
control system.
DRICO
slife
is an electronic control unit with safety functionality. It is used as a control system for
the operation of gates in the industrial environment. It contains a frequency converter and can
operate a three-phase motor with up to 0.75 kW electrical power on a one-phase network. The
frequency converter makes gate soft-start and braking possible. The maximum frequency
transmitted by the converter is limited to a maximum of 75 Hz.
3.1 Requirements
The control system is only fully functional in the ready-to-use gate system. Additional external
components may also be required, for example:
- Drive
(electric motor and transmission)
- Command input devices
(switch/button)
- Signal devices
(blinking lights/horns)
- Sensor elements
(Safety edges/light barriers)
These a
re not included in the control system‘s scope of delivery.
3.2 Technical characteristics
The DRICO
slife
FU12 has the following characteristics:
Auto-configuration and comprehensive default settings for standard gate systems
Comprehensive parameterization system
2 inputs for the deadman (Hold to run) operator buttons OPEN and CLOSE
inputs for the automatic control device STOP, OPEN, PartialOPEN and TOGGLE switching
impulse (OPEN, STOP, CLOSE, STOP, ...)
2 inputs for the gate end switches OPEN and CLOSE
output relays (normal open contacts) for blinking light, gate position OPEN and position
CLOSED, Motor brake, maintenance requirement
INDUS and SENTIR edge inputs can be connected via screw terminals, for the evaluation of
the moving and fixed safety contact edges
Separate input for light barrier
Operation and configuration via rotary and selection switch
7-segment display for status reports
LC display for diagnostic display and parametrization via menu navigation
Optional radio receiver for hand-held radio transmitters for remote control of the gate