The output relay „Rel2“ is configured in such a way at the factory that it is closed when the gate‘s
OPEN position is reached. The output relay „Rel3“ is configured in such a way that it is closed at
„Gate CLOSED“.
If one of these two rel
ays is used for another function (e.g. „courtyard light“), the status display
function must first be taken out of the configuration for the relays. Only then can the corresponding
relay be parameterized with a new function. The „Gate CLOSED“ status display
on relay 3 is
deactivated as follows:
-
Menu: „Service Menu“, „Password Input“: Enter password
-
Menu: „Settings“, „Status Indicator“, „Outp.GateSt. 2“: Set to „
----
“
In this way the gate status 2 (Gate CLOSED) function is no longer signaled with relay 3. This relay
can now be parameterized with a new function (e.g. “Light Output“ as described in section:
6.3.11).
6.3.13 Additional electrical brake
An additional electrical brake can be parametrized instead of a gate status display to an output
relay ‘Rel2’ or ‘Rel3’. The relay switches as soon as the motor is supplied by the control unit
(brake is released). With the shut-down of the motor the relay is released (brake fix).
-
Menu: „Settings“, „Spec.Parameter“, „Outp.Ext.Brake“: set to „Relx“
6.3.14 Parameterizing a maintenance cycle counter
In order to guarantee regular gate maintenance, it is possible to define a maintenance requirement
after a specific number of gate movements. If the defined number of gate movements is reached
or exceeded, the event „Maintenance requirement“ is triggered in the control system. In the event
of an active maintenance requirement, the message
< MAINTENANCE >
Required
is shown on the display. In the delivery state, the value for the number of gate movements is
preconfigured with 5.000 movements.
Maintenance can be parameterized as follows:
-
Menu: „Service Menu“, „Password Input“: Enter password
-
Menu: „Settings“, „SpecParameter“, „Cycles ToService“: Set to „zz“
The entry „zz“ defines a number of cycles (in 1000 cycles) that the gate goes through to „open“
and „close“. The counter is increased each time the „CLOSE“ end position is reached. The control
system activates the maintenance requirement once the counter reaches the preconfigured value
of „zz“.
The value “zz“ is the
maximum number of gate cycles (in 1000 cycles) (CLOSE, OPEN, CLOSE)
until the service requirement. The settable values signify the following:
0 = no maintenance requirement according to number of movement cycles
25 = 25000 completed OPEN and CLOSE movements
6.3.15 Parameterizing a maintenance interval
In order to guarantee regular gate maintenance, it is possible to define a maintenance requirement
after a specific time (number of months). The event „Maintenance requirement“ is triggered in the
control system once the defined time is reached or exceeded. In the event of an active
maintenance requirement, the message is shown on the display.