Reference-/
error no.
Text
Meaning
236
Reference Active
A gate reference run was activated
238
OP/CL-StartActive
The motor controller‘s program start was interrupted due
to an active movement command
(check and deactivate inputs)
239
LBtestError
There was an error in the light barrier test
241
SPI BCC Err
A checksum error occurred during communication
between the controllers
242
SPI ID Err
A data error was detected during communication between
the controllers
243
ParameterErr
An error occurred while writing data in the memory
247
VariantErr
The loaded parameter set and motor controller program
variant do not go together
248
Par.LoadingErr.
An error was detected while transmitting the parameter
set from the peripheral controller to the motor controller
(CRC16 checksum)
249
Menupointer Err
Menu program pointer error
(error in the branching of the menu structure)
250
ProgramInit.
In the system log: The program was initialized
(deletion and initiation of parameter memory)
In the event log book: The program was restarted
253
RESET
Program triggers a software restart