The following display appears by rotating the selection switch clockwise to the right to a guide
groove:
Main Menu
2 Service Menu
This menu item can be activated by briefly pressing the selection switch; one goes a menu level
deeper in the service menu:
Service Menu
1 Password Input
This menu item is also activated by pressing the selection switch and you are able to enter the
password:
Password Input
Value: 33333
One can change the preset, displayed value by rotating. In the process, quicker rotation
movements result in a faster change in of the values.
The configured value is saved by pressing, and the previous menu item is shown again:
Service Menu
1 Password Input
If the password was entered correctly, the menu items and entries covered by the password can
be selected immediately. The correct password remains valid for 10 minutes. It automatically
resets itself to the value 33333 if not additional entries are made. If one enters a number other
than the correct password, the number remains saved and is not reset to the value 33333.
By pressing the selection switch for two seconds, the main menu item
Main Menu
QUIT Menu
can be selected at any time. The control system executes a restart of the program (reset) once
this menu item is confirmed and returns to the active operating mode.
6.2 Setting up the gate
The following installations and parameterizations make sense and are necessary for the start-up
of the DRICO
slife
. All configurations and displays that can only be accessed by a trained
technician are protected with a password.
6.2.1 Installation of the command keys for deadman operation
At least one OPEN and one CLOSE button must be connected for deadman operation before a
gate can be put into operation. These buttons are necessary for setting up the end positions. The
following items must be completed in sequence.