When starting the gate system, the motor‘s direction of rotation must be taken into consideration
so that the gate also moves in the desired direction when the OPEN button is activated. If
necessary, the motor connections „V“ and „W“ must be exchanged or the motor‘s direction of
rotation must be changed per software via the configuration in the menu.
4.2.2 Instructions for suitable EMC installation
Attention!
Damage to other devices in the immediate vicinity of the control device may occur in the event
of unsuitable EMC installation.
The DRICO
slife
is a frequency converter control system. Frequency converters are devices that can
generate electromagnetic interferences in your surroundings due to their circuitry.
Thus, only a shielded line can be used as a motor line. The shield must be connected to the motor via
an EMC screw connection and in the control system to the intended PE clamp.
4.2.3 Supply for external consumers with 230 V
AC
External appliances for the control system that work with 230 V
AC
power supply can be connected
via the secured voltage output with the terminal designation „L“ on the control system‘s power
board (figure 3 No. 6.) The maximum load, determined by the integrated safety fuse (figure 3 No.
7) must be observed in the process.