6.4.2 Time for closing from the PartialOPEN position
The control system can automatically close the gate again upon reaching the PartialOPEN
position after a configurable time (1 to 255 seconds). This function is only active in automatic
operation and after reaching the PartialOPEN position.
-
Menu
: „Settings“, „Set Timer“, „TMR KeepPartOPEN“: Set to „xxx“
Example:
A preconfigured parameter „TMR KeepPartOPEN “ with the value 5 causes a time counter that
automatically closes the gate after five seconds to be started in automatic operation once the
PartialOPEN position is reached. The time counter restarts if during this time an additional
PartialOPEN command is given or if a static PartialOPEN permanent command applies.
This value can also be entered by the customer without entering the password.
6.4.3 Time for closing the gate from intermediary positions
If the gate should always automatically close after a configurable time (1 to 255 seconds)
regardless of the gate‘s position (automatic closure), this function can be configured via the
parameter „TMR
autom. close“. This function is only active in automatic operation and affects all of
the gate‘s positions except for the OPEN end position and the PartialOPEN position.
-
Menu: „Service Menu“, „Password Input“: Enter password
-
Menu: „Settings“, „Set timer“, „TMR Autom. Close“: Set to „xxx“
Example:
A preconfigured time 20 causes a time counter that automatically closes the gate after 20 seconds
to be started in automatic operation when the motor stops outside of the CLOSE end position (not
with STOP button).
This value can also be entered by the customer without entering the password.
6.5 Support for diagnose
The DRICO
slife
has got a diagnose menu which facilitates the start-up of the control system and
the repair of arised mistakes.
6.5.1 Version display
The control system version can be displayed as follows:
-
Menu: „Identification“, „Master Version“: The displayed letters and number combination
uniquely identifies the software used
-
Menu: „Identification“, „Gate Type“: The displayed text shows the gate desig
nation for
which the control system, software and saved parameters are defined
-
Menu: „Identification“, „Serialnumber“: The control system serial number is displayed
The following version parameters can also be seen after the correct password is entered:
-
Version of the motor controller program
-
Version of the peripheral controller program
-
Version of the loaded parameter table
-
Version of the motor controller‘s boot loader
-
Version of the peripheral controller‘s boot loader