Check for correct connection of the light barrier function with the ’Sensor depiction’
display and the reaction for gate movement in the CLOSE direction in automatic
operation!
6.3.10 Connecting a blinking light
The output for relay „Rel1“ is configured f
or the blinking function at the factory. An automatic
blinking light for +24V is connected to relay „Rel1“ as follows:
-
Switch control system to a zero-potential state
-
C24 V power supply to output relay „Rel1“
-
Connect blinking light to output rel
ay „Rel1“ and to GND (0 volt)
-
Switch on power supply for control system
The control system turns on the blinking light as soon as a movement command is detected and
can be executed by the control system. It remains active until the motor is activated.
The relay for the blinking light is also turned on three seconds before an automatic gate supply
and remains active during the gate supply.
In some countries regulations specify that the advance warning must be active for three seconds
prior to gate movement (also before opening). Only then the motor is activated and the gate
moves. This general advance warning can be switched on or off as follows:
-
Menu: „Service Menu“, „Password Input“: Enter password
-
Menu: „Settings“, „Set timer“, „Flashlight Premon“:
Value 0: general advance warning time switched off
Value 1: general advance warning time switched on
6.3.11 Setting up lighting (courtyard light)
The control can activate lighting that automatically illuminates the gate area in the event of
movement, for example. The function can be configured on Rel2 or Rel3 if the assignment of
these relays was first released via the gate status display. The configuration for Rel3 is described
here as an example.
-
Switch control system to a zero-potential state
-
Connect lamp to output relay Rel3
-
Switch on power supply for control system
-
Menu: „Service Menu“, „Password Input“: Enter password
-
Menu: „Settings“, „Set Timer“, „Light Output“: Set to „Rel3“
-
Menu: „Settings“, „Set Timer“, „Lighting (s)“: Set the desired time (in
seconds).
The value must be greater than 0, otherwise the relay is not activated
The lamp connected to „Rel3“ will now be turned on by the control system as soon as a movement
command is detected. The lamp continues to be illuminated for the corresponding time (1 to 1800
seconds) after the motor is shutdown. This parameter „Lighting (s)“ can also be changed by the
customer without entering the password.
6.3.12 Connecting a gate status display
The DRICO
slife
can signal two different gate states and an error state via relays.