The time counter for the number of months that have gone by and the cycle counter for the
number of gate movements are reset to 0.
6.3.19 Resetting all parameter settings
In the service menu there is a menu item which one can reset all parameters to the preconfigured
values (factory settings).
-
Menu: „Service Menu“, „Password Input“: Enter password
-
Menu: „Service Menu“, „Par. Restore“
The configurable values (timer, sensors, inputs/outputs, motor values and operating mode) are
thus reset to the pre-configuration.
6.3.20 Setting the boost value
Frequency converters supply the connected electric motor at lower frequencies than 50 Hertz with
less than 230 AC voltage. With increasing frequency the voltage is increased, too, until 230 AC is
reached at 50 Hz. This makes possible to limit the maximum current and to not stress the whole
system excessively. If the motor doesn’t create enough torque at low revolutions the tension an
d
with it the current supply can be increased at low frequency by increasing the boost value.
-
Menu: „Service Menu“, „Password Input“: Enter password
-
Menu: „Service Menu“, „PWM Boost“:
set value
Attention!:
consequence of setting up PWM Boost is a higher current conduction
6.4 Automatic gate movement timing
Some gate movements can be automatically triggered by predefined time settings. The
parameterization of these times per menu should be shown here.
6.4.1 Configure automatic closing (hold-open time)
The control system can automatically close the gate again upon reaching the OPEN end position
after a configurable time (1 to 999 seconds). This function is only active in automatic operation
and after reaching the OPEN end position.
-
Menu: „Settings“, „Set Timer“, „TMR Keep Open“: Set to „xxx“ seconds
Example:
A preconfigured parameter „TMR Keep Open“ with the value 5 causes a time counter that
automatically closes the gate after five seconds to be started in automatic operation once the
OPEN end position is reached. The time counter restarts, if an additional OPEN command is given
or an installed light barrier is activated during this period.
This value can also be entered by the customer without entering the password.