4.3 Input and output wiring
There are two terminal blocks for the connection of external devices arranged next to one another
on the control system. The left block is intended for relay outputs (figure 1: General view No.: 9),
while control devices and sensors can be connected on the right block (figure 1: General view No.:
10 and 11). The terminal designation is printed on the board below the terminals.
Said terminals are also shown individually in figure 4 below for better identification.
Figure 4: Connection of external devices
4.3.1 Power supply for external devices with 24 V
DC
An isolated and voltage-stabilized 24 V
DC
power supply that can supply a maximum 500 mA current is provided in
the control system for the power supply for external devices, control devices and sensors. This supply voltage is
protected on the circuit board with a fuse with automatic reset. The 24 volts are available on the lower terminal
strip (Image 4 No. 10.1) on the left contact points No. 1
0.2) with the designation „0V“.
Image No. Terminal No.
Designation
Function
10.1
1 to 4
+24 V
+24 Volt DC power supply
10.2
5 to 8
0 V
Ground potential for external 24 V consumers
4.3.2 Connection of the control devices and end switches
The inputs for the control devices and control system are marked on the upper terminal strip with „In1“ to
„In8“ (figure 4 No. 11.3) and assigned the foll