- Switch control system to a zero-potential state
- Connect the voltage supply for the buttons to 24 V
- Connect buttons for OPEN (deadman button) to the input terminal In8 (make contact)
- Connect buttons for CLOSE (deadman button) to the input terminal In7 (make contact)
- Switch on power supply for control system
-
Check buttons‘ function
6.2.2
Change drive‘s direction of rotation
If it is determined during the very first start-up of the motor on the gate that the gate moves in the
wrong direction, the motor‘s direction of rotation can
be established by exchanging two phases of
the motor line. On the other hand, it is also possible to change the direction of rotation via a
software setting. This change is done as follows:
-
Menu: „Service Menu“, „Password Input“: Enter password
-
Menu: „Service Menu“, „Mot.RotationDir.“: Change value to „1“
-
Correct gate movement must be checked again!
6.2.3 Parameterize immobile safety contact edges
The immobile safety contact edges are always activated at the factory.
-
Switch control system to a zero-potential state
-
Connect contact edge(s) for the OPEN direction to the “SKL open” input terminal
-
Connect contact edge(s) for the CLOSE direction to the “SKL close” input terminal
-
Switch on power supply for control system
-
Check for correct connection of the edge
s with the ‘sensor depiction’ display and the
gate‘s reaction in the corresponding movement direction in automatic operation!
If the immobile safety contact edge is not necessary in the CLOSE direction, for example, it can be
deactivated as follows:
-
Me
nu: „Service Menu“, „Password Input“: Enter password
-
Menu: „Settings“, „Safeties“ „Stat.edge CLOSE“: Set value to „0“
-
Check for correct gate movement in the corresponding movement direction in automatic
operation!
6.2.4 Parameterize accompanying safety contact edges
The accompanying safety contact edges are NOT activated at the factory. The INDUS system can
be activated as follows:
-
Switch control system to a zero-potential state and connect INDUS-System
-
Switch on power supply for control system
-
Menu: „Service Menu“, „Password Input“: Enter password
-
Menu: „Settings“, „Safeties“, “Mov.Edge CLOSE”: set the value to ‘1’
-
Menu: „Settings“, „Safeties“, “Mov.Edge OPEN”: set the value to ‘1’
-
Check for correct connection with the display ‘sensor depiction’ and the gate’s reaction in
the corresponding movement in automatic operation
6.2.5
Installation of the gate‘s end switches
The DRICO
slife
control system is preconfigured for the operation of doors and gates with end
switches. Various designs for end switches (proximity switches, mechanical switches, etc.) can be
used, but all must be designed as normally closed contacts.