9
Technical data
9.1 DRICO slife 150 FU 12
Electrical values
Voltage supply
1 Phase 230 V
ac
/ N / PE
±10%
50/60 Hz
Factory protection fuse
max. 10 A
Power consumption (without
motor or external consumers)
16 W
External power supply 230 V
230 V
AC
±10% 50/60 Hz
protected on the circuit board with 6.3 A delay
External power supply 24 V
24 V
DC
stabilized (±5%) max. 500 mA
(protected with self-resetting semiconductor fuse)
Control inputs
24 V
DC
/ typically 4 mA
< 12 V: inactive -> logical 0
> 18 V: aktive -> logical 1
(internally galvanically separated)
Relay outputs
(1
max. 250 V
AC
/ 1 A
Maximum electrical capacity
control unit
0,75 kW (7
Hz … 50
Hz)
Maximum electrical capacity
motor (motor shaft)
ca. 0,55 kW
Mechanical values
Housing
ABS with aluminium cooling element
Dimensions W x H x D
160 x 270 x 110 mm
Weight
2,3 kg
Protection class
IP54
Temperature range
-20 °C bis +55 °C
Humidity range
max. 99% non-condensing