6.5.2 Active movement commands in switch on process
During start up the DRICO
slife
executes a test of the configured inputs. Active movement
commands (normally closed contacts that are statically pulled to GND, make contacts that are
statically pulled to +24 V) result in the control system not yet starting. The recognized sample for
the inputs is shown on the display:
OP/CL-StartActiv
Value: 01101010
For example, the input „In7“ (deadman button CLOSE) was active during start
-up with regard to
the display shown. The control system‘s pro
gram once again executes a restart after a change to
the relevant input signals.
Information:
This function is suppressed for inputs with the function „PartialOpen“ and
„OPEN“, as there may also be static signals (e.g. external clock timers) on this inpu
ts at start-
up. However, the static signals still do not result in uncontrolled gate movement during start-
up.
6.5.3 Gate status
All information that represents the current status of the control system in connection with the gate
is sum¬marized in the menu Gate status.
The menu is reached via „Diagnostics“ and has the following subitems:
Menu
Display
Meaning
Gate Situation
OPEN / CLOSE /
PartialOPEN /
STOPPED
The current gate status recognized by the software is
shown.
Input:
87654321
Value: 00000010
The
logical values on the control system‘s input terminals
are shown. The series corresponds to inputs In8 to In1.
An active input is shown with „1“. In the example, input
In2 has +24 V potential.
Output 54321
Value: 00010
The status of the output relays is shown with its logical
values. An activated relay is marked with „1“. The
sequence corresponds to outputs Rel5 to Rel1. Relay
Rel2 is activated in the example.
Completed
Cycles
5217 / 19
The total number of runs and the number of runs since
the last maintenance are shown. Here, a run is an
OPEN-CLOSE cycle.
Last Service
7 Month
The number of months that have passed since the last
maintenance are shown here.
A maintenance interval based on the number of gate movements can be defined to ensure regular
gate maintenance.
In the event of an active maintenance requirement (number of run cycles and/or number of
operating months reached), the message „< MAINTENANCE > required“ is shown in the display.