Chapter IV Local Operation
77
ARRAY
MODE
CCL
;
Set the mode
SYST:STAT
TRAN
;
Enter into transient mode
CURR
1
;
Set the transient low level
CURR: TLEVel
5
;
Set the transient high level
TRAN:LTIME
1ms
;
Set the low level time
TRAN:HTIME
1ms
;
Set the high level time
TRAN:RTIME
10us
;
Set the time for rising edge
TRAN:FTIMR
10us
;
Set the time for falling edge
TRAN:MODE
PULS
;
Select transient operation mode
INP
ON
;
Open the load
INIT
;
Trigger initialization
TRIG
;
Execute one pulse operation
4.7.3 Toggle Transient Operation
Example :
If the load is in external trigger mode, set the resistance level periodically switch
between 200Ω and 500Ω, the time for rising edge to 10ms, the high level time to 200ms, the time
for falling edge to 10ms and the low level time to 100ms. The load is in toggle transient operation
and executes one trigger simultaneously. The procedures are shown as below:
Step 1:
Press dynamic
key to enter into transient mode and the parameter setting menu;
press
key to enter into
mode; then press dynamic
key to
mode;
Step 2:
Select “L_Level” via
key or
and
keys; enter the transient low level
0.2 by the number keypad, or via knob with
and
keys; then press
key to
confirm;
Step 3:
Select “H_Level” via
key or
and
keys; enter the transient high level
0.5 by the number keypad, or via knob with
and
keys; then press
key to
confirm;
Содержание 3750A
Страница 1: ...Contents USER S MANUAL 375X SERIES ELECTRONIC LOAD ...
Страница 63: ...Chapter III Installation 59 ARRAY ...
Страница 114: ...Chapter V Remote Programming Operation 110 ARRAY Frame Diagram Fig 1 ...
Страница 115: ...Chapter V Remote Programming Operation 111 ARRAY ...
Страница 116: ...Chapter V Remote Programming Operation 112 ARRAY Fig 2 ...
Страница 120: ......