Chapter II Functions & Features
23
ARRAY
Figure 2-1 Constant Current Mode
2.3.1.1 Current Setting Range
The setting ranges for the load are listed as follows:
Model
3750A
3751A
3752A
3753A
3754A
3755A
3756A
Mode
CCL
0
~
6A
0
~
6A
0
~
6A
0
~
6A
0
~
8A
0
~
8A
0
~
8A
CCH
0
~
100A 0~150A
0
~
75A 0
~
160A 0
~
180A 0
~
240A 0
~
260A
If the input of the load is ON, the load will be turned off automatically when the mode is changed.
For example: When the load is switched from CCL to CCH, the input of the load will be off
automatically. Also of note is that the current set level may change with the current set mode and
the changed value is the current value in current mode. For example: the original setting is CCH
150.000A. When the load is switched from CCH to CCL, the current set value will become the
present current value 1A in CCL mode.
2.3.1.2 Immediate Current Level
The immediate current level is the current set value in CC mode, which can be set in parameter set
menu in current mode, or can be set via remote command: CRRRent<NRf+>. In CC mode, the
immediate current level can directly be modified via
,
or knob.
2.3.1.3 Triggered Current Level
The triggered current level is the preset current value in the load, which will become the
Содержание 3750A
Страница 1: ...Contents USER S MANUAL 375X SERIES ELECTRONIC LOAD ...
Страница 63: ...Chapter III Installation 59 ARRAY ...
Страница 114: ...Chapter V Remote Programming Operation 110 ARRAY Frame Diagram Fig 1 ...
Страница 115: ...Chapter V Remote Programming Operation 111 ARRAY ...
Страница 116: ...Chapter V Remote Programming Operation 112 ARRAY Fig 2 ...
Страница 120: ......