Chapter II Functions & Features
27
ARRAY
Fig. 2-3 Constant Resistance Mode
2.3.3.1 Resistance Setting Range
The setting ranges of the resistance for the load are listed as follows:
Model
375XA
Mode
CRL
0.01Ω
~
240000Ω
CRH
0.2Ω
~
2400KΩ
If the input of the load is ON, the load will be turned off automatically when the mode is changed.
For example: When the load is switched from CRL to CRH, the input of the load will be off
automatically. Also of note is that the voltage set level may change with the voltage set mode to be
suitable for the new range. For example: the original setting is CRH 10.000Ω. When the load is
switched from CRH to CRL, the voltage set value will become the minimum voltage value
0.0000Ωin CRL mode.
2.3.3.2 Immediate Resistance Level
The immediate resistance level is the resistance set value in CR mode, which can be set in
parameter set menu in resistance mode, or can be set via remote command: RESistance <NRf+>.
In CR mode, the immediate resistance level can directly be modified via
,
or knob.
2.3.3.3 Triggered Resistance Level
The triggered resistance level is the preset resistance value in the load, which will become the
Содержание 3750A
Страница 1: ...Contents USER S MANUAL 375X SERIES ELECTRONIC LOAD ...
Страница 63: ...Chapter III Installation 59 ARRAY ...
Страница 114: ...Chapter V Remote Programming Operation 110 ARRAY Frame Diagram Fig 1 ...
Страница 115: ...Chapter V Remote Programming Operation 111 ARRAY ...
Страница 116: ...Chapter V Remote Programming Operation 112 ARRAY Fig 2 ...
Страница 120: ......