Chapter IV Local Operation
71
ARRAY
Step 6:
Enter the voltage level 50.000 by the number keypad, or via knob with
and
keys;
Step 7:
Press
key to confirm;
Step 8:
Press
key to open the load.
The corresponding SCPI commands of the above procedures should be as follows:
MODE
CCH+CV
;
Set the mode
CURR
80
;
Set the current level
VOLT:ADD:LIM 50
;
Set the voltage limit level 50V
INP
ON
;
Open the load
4.6.2 CR+CV Mode
Example 1:
Take 3751A as an example, in CRL mode, set the resistance level to
1.5Ω
, the voltage
limit to 20V. Turn on the load. The procedures are shown as belows:
Step 1:
Switch to
mode by pressing
and
key simultaneously;
Step 2:
Switch to parameter setting menu via
and
keys;
Step 3:
Enter the resistance level 1.5 by the number keypad, or via knob with
and
keys;
Step 4:
Press
key to confirm;
Step 5:
Switch to voltage limit option via
and
keys;
Step 6:
Enter the voltage level 20.000 by the number keypad, or via knob with
and
keys;
Step 7:
Press
key to confirm;
Step 8:
Press
key to open the load
.
Содержание 3750A
Страница 1: ...Contents USER S MANUAL 375X SERIES ELECTRONIC LOAD ...
Страница 63: ...Chapter III Installation 59 ARRAY ...
Страница 114: ...Chapter V Remote Programming Operation 110 ARRAY Frame Diagram Fig 1 ...
Страница 115: ...Chapter V Remote Programming Operation 111 ARRAY ...
Страница 116: ...Chapter V Remote Programming Operation 112 ARRAY Fig 2 ...
Страница 120: ......