AC and DC Parameters
7-4
Copyright © 2001, 2004 ARM Limited. All rights reserved.
ARM DDI 0210C
The timing parameters used in Figure 7-1 on page 7-3 are listed in Table 7-1.
Table 7-1 General timing parameters
Symbol
Parameter
Parameter type
T
addr
MCLK
r to address valid
Maximum
T
ah
Address hold time from
MCLK
r
Minimum
T
bld
MCLK
r to
MAS[1:0
] and
LOCK
Maximum
T
blh
MAS[1:0]
and
LOCK
hold from
MCLK
r
Minimum
T
cdel
MCLK
to
ECLK
delay
Maximum
T
exd
MCLK
f to
nEXEC
and
INSTRVALID
valid
Maximum
T
exh
nEXEC
and
INSTRVALID
hold time from
MCLK
f
Minimum
T
mdd
MCLK
r to
nTRANS
,
nM[4:0
], and
TBIT
valid
Maximum
T
mdh
nTRANS
and
nM[4:0]
hold time from
MCLK
r
Minimum
T
msd
MCLK
f to
nMREQ
and
SEQ
valid
Maximum
T
msh
nMREQ
and
SEQ
hold time from
MCLK
f
Minimum
T
opcd
MCLK
r to
nOPC
valid
Maximum
T
opch
nOPC
hold time from
MCLK
r
Minimum
T
rwd
MCLK
r to
nRW
valid
Maximum
T
rwh
nRW
hold time from
MCLK
r
Minimum
Содержание ARM7TDMI
Страница 6: ...Contents vi Copyright 2001 2004 ARM Limited All rights reserved ARM DDI 0210C ...
Страница 10: ...List of Tables x Copyright 2001 2004 ARM Limited All rights reserved ARM DDI 0210C ...
Страница 14: ...List of Figures xiv Copyright 2001 2004 ARM Limited All rights reserved ARM DDI 0210C ...
Страница 46: ...Introduction 1 26 Copyright 2001 2004 ARM Limited All rights reserved ARM DDI 0210C ...
Страница 120: ...Coprocessor Interface 4 18 Copyright 2001 2004 ARM Limited All rights reserved ARM DDI 0210C ...
Страница 142: ...Debug Interface 5 22 Copyright 2001 2004 ARM Limited All rights reserved ARM DDI 0210C ...
Страница 276: ...Differences Between Rev 3a and Rev 4 C 6 Copyright 2001 2004 ARM Limited All rights reserved ARM DDI 0210C ...
Страница 282: ...Glossary Glossary 6 Copyright 2001 2004 ARM Limited All rights reserved ARM DDI 0210C ...