14 Operation on an ISDN Access
ARGUS 145
PLUS
247
Call parameters
Two different parameters can be set for (ISDN) calls generated
on both the network-side (ARGUS in NT mode) and on the user-
side (ARGUS in TE mode):
1. Type of number (TON) for the CGN (=CGPN) or CDN
(=CDPN) element of a SETUP signal
Network-side:
Net CGN TON
Net CDN TON
User-side:
User CGN TON
User CDN TON
2. Numbering Plan (NP) for the CGN (=CGPN) or CDN (=CDPN)
element of a SETUP signal
Network-side:
Net CGN NP
Net CDN NP
User-side:
User CGN NP
User CDN NP
Default setting:
unknown
CGN/CDN subaddress
CGN/CDN subaddress type: User specific and NSAP
- Default setting:
User specific
UUI
Services
Three user-specific services (User spec. 1 to User spec. 3) can
entered and saved.
The three Info elements, BC, HLC and LLC (switch using the left
softkey) must be entered for each user specific service in
hexadecimal using the keypad and softkeys
<A..F>
(e.g. to
enter a C press the softkey three times, to enter an F press it six
times).