DMX ETH Manual
page 66
rev 1.16
SCVX
Description:
Write:
Set s-curve enable.
Range is from 0 or 1
Syntax:
Write:
SCVX=[0 or 1]
SCVX=[variable]
Note: If s-curve is enabled for an axis, on-the-fly speed feature can not be used for the
corresponding axis.
Examples:
SCVX=1
;***Sets axis to use s-curve acceleration: on-the-fly speed
; change is NOT allowed for this axis.
SLX
Description:
Write:
Set StepNLoop closed-loop mode
Range is from 0 or 1
Syntax:
Write:
SL=[0 or 1]
Examples:
SL=1 ;***Sets axis to closed-loop mode
SLSX
Description:
Read:
Get StepNLoop status
Syntax:
Read:
[variable]=SLSX
Conditional:
IF SLSX =[variable]
ENDIF
IF SLSX =[value]
ENDIF
Examples:
IF SLSX != 0
ECLEARX
ELSE
ECLEARSX
ENDIF
SSPDX
Description:
Write:
Set on-the-fly speed change for an individual axis.
Syntax:
Write:
SSPDX=[value]
SSPDX=[variable]
Note: If s-curve is enabled for an axis, on-the-fly speed feature cannot be used for the
corresponding axis.