DMX ETH Manual
page 48
rev 1.16
8. Ethernet Communication Protocol
DMX-ETH uses 10Mbps Ethernet ASCII communication over TCP/IP.
Communication between the PC/PLC and DMX-ETH is done using standard socket
programming.
Socket Settings
Port:
5001
ASCII Protocol
Sending Command
ASCII command string in the format of
[ASCII Command][NUL]
[NUL] character has ASCII code 0.
Receiving Reply
The response will be in the format of
[Response][NUL]
[NUL] character has ASCII code 0.
Examples:
For querying the x-axis polarity
Send: POX[NUL]
Reply: 7[NUL]
For jogging the x-motor in positive direction
Send: JX+[NUL]
Reply: OK[NUL]
For aborting any motion in progress
Send: ABORT[NUL]
Reply: OK[NUL]