DMX ETH Manual
page 52
rev 1.16
VER
Get firmware version
VXXX
X[value]
Moves the motor to absolute position value using the
HSPD, LSPD, and ACC values.
OK
Z+
Homes the motor in positive direction using the Z index
encoder channel ONLY.
OK
Z-
Homes the motor in negative direction using the Z index
encoder channel ONLY.
OK
ZH+
Homes the motor in positive direction using the home
switch and then Z index encoder channel.
OK
ZH-
Homes the motor in negative direction using the home
switch and then Z index encoder channel.
OK
Table 9.0
Error Codes
If an ASCII command cannot be processed by the DMX-ETH, the controller will reply
with an error code. See below for possible error responses:
Error Code
Description
?[Command]
The ASCII command is not understood
?ABS/INC is not in
operation
T[] command is invalid because a target position move is not in
operation
?Bad SSPD Command SSPD move parameter is invalid
?Index out of Range
The index for the command sent to the controller is not valid.
?Moving
A move or position change command is sent while the controller is
outputting pulses.
?S-curve on
Cannot perform SSPD move because s-curve is enabled
?Speed out of range
SSPD move parameter is out of the range of the SSPDM speed
window.
?SSPD Mode note set
Cannot perform SSPD move because SSPDM is not set
?State Error
A move command is issued while the controller is in error state.
?Sub not Initialized
Call to a subroutine using the
GS
command is not valid because the
specified subroutine has not been defined.
Table 9.1
Содержание DMX-ETH
Страница 10: ...DMX ETH Manual page 10 rev 1 16 3 Dimensions All dimensions in inches Controller Figure 3 0 NEMA 17 Figure 3 1...
Страница 13: ...DMX ETH Manual page 13 rev 1 16 Figure 4 1 Torque Curve NEMA 23 Figure 4 2...
Страница 14: ...DMX ETH Manual page 14 rev 1 16 Figure 4 3...
Страница 17: ...DMX ETH Manual page 17 rev 1 16 DMX ETH Interface Circuit Figure 5 2...
Страница 21: ...DMX ETH Manual page 21 rev 1 16 Main Control Screen Figure 6 3 A B C D E F L K J H M G I...