Safety
7
MAXXfl o EVO 150/302
CAUTION
If the water system is not in use for periods exceeding 14 days, there is an increased risk of
corrosion on all copper parts and an increase in bacterial growth. Follow the recognised measures
for Anti-legionella in section 5.4.2. to manage this risk
2.2 REGULATIONS AND STANDARDS
This heater must be installed in accordance with relevant Standard Specifi cations, Codes of Practice and cur-
rent Building Regulations, together with any special regional requirements of the Local Authorities, Gas under-
taking and Insurance Regulations for the Electrical Equipment of Buildings. The installation of this heater must
be in accordance with the relevant requirements of:
•
Health and safety at work act 1974
•
Building regulations 2010
•
Electricity at work regulations 1989
•
Management of health and safety at work regulations 1998
•
Manual handling regulations 1992
•
Water Supply (Water Fittings) Regulations 1999 (England and Wales)
•
Water Supply (Water Fittings) Byelaws 2014 (Scotland)
•
Water Supply (Water Fittings) Regulations 2009 (Northern Ireland)
•
BS 7671 - Requirements for electrical installations, IET wiring, regulations
•
BS 6644 - Specifi cation for the installation of Gas fi red hot water boilers for rated inputs between 70kW
(net) and 1.8 MW
•
BS 7074-2 - Applications selection and Installation of expansion vessels and ancillary equipment for sealed
water systems.
•
BS 6880:1 Code of practice for low temperature hot water heating systems of output greater than 45kW.
•
BS 6880:2 Code of practice for low temperature hot water heating systems of output greater than 45kW.
•
BS 6880:3 Code of practice for low temperature hot water heating systems of output greater than 45kW.
•
CP 342:2 Code of practice for centralised hot water supply. Buildings other than individual dwellings.
•
IGE/UP/1 - Strength testing/tightness testing/direct purging of industrial and commercial gas installations
•
IGE/UP/2 - Installation pipework on industrial and commercial premises
•
IGE/UP/10 - Installation of fl ued gas appliances in industrial and commercial premises.
•
IGE/UP/16 - Design for Natural Gas installations on industrial and commercial premises with respect to
Dangerous Substances and Explosive Atmospheres Regulations (DSEAR)
CAUTION
These manufacturer’s notes must not be taken in any way as over-riding statutory obligations.