From previous page
Does damper blade move to
the full open position?
Is there pilot flame?
Does Main Burner operate?
Does burner continue until
thermostat set point is
reached? See setting display in
Service Mode and displaying
temperature sensors.
Does water heater begin to
operate?
Check for debris limiting
damper rotation. If no debris,
replace damper.
Error code #62 on display. See
“Pilot Will Not Light”.
Error code #55 on display.
Remove damper from heater
and jump black & yellow wires
of heater harness.
Error code #62 on display. See
“Pilot Lights, No Flame Signal”
Error code #63 on display. See
“Main Burner Short Cycles”.
Error code #56 on display.
Check for debris limiting
damper rotation. If no debris,
replace damper
Does the flue damper rotate to
the fully closed position?
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
System okay
Caution
Use Caution Not to Damage Connectors when making
Voltage Measurements or Jumping Terminals
Fig. 40
Example of error code shown on control display