Issue 2 14/07/16
57
Fault Finding
8
8.6 LPG permanent pilot models - LPG HIflo ranges
Fault
Loud whistling noise
Action
Check burner primary air shutter settings are correct to dimensions given below.
If not reset to dimensions given below.
If the whistling persists continue to reduce the settings until the whistling stops.
Heater Model
Air shutter dimension A in mm
L32/143
8
L65/169
5
L81/251
10
L62/309
8
L54/399
8
Locking Pin
A
Air Shutter
Burner
Injector