10
Issue 2 14/07/16
2
Technical Data
2.2 Standard Range (LPG)
Andrews Model No.
L24/31 L32/35 L40/36 L63/71 L84/74
Storage Capacity
I
109
145
182
286
382
Recovery thro’ 50°C
I/h
141
163
163
322
336
Recovery thro’ 56°C
I/h
113
127
131
258
269
Heat Input Gross
kW
9.5
11.0
11.0
22.0
22.0
Heat Input Net
kW
8.6
10
10
20
20
Gas
LPG CAT I
3
Inlet Gas Pressure Propane
mbar
37
37
37
37
37
Inlet Gas Pressure Butane
mbar
28
28
28
28
28
Gas Flow Rate
m
3
/h
0.36
0.41
0.41
0.83
0.83
Gas Connection
Rc (in BSP Int) 1/2
1/2
1/2
1/2
1/2
Flue Gas Temp.
°C
180
180
185
125
130
Flue Gas Volume
m
3
/h
16
16
23
28
34
Gas Injector Orifice Diameter
mm
1.5
1.6
1.6
2.25
2.25
Flue Size (Secondary)
mm
100
100
100
125
125
Cold Water Feed Connection
R (in BSP/Exl) 1
1
1
1
1 1/4
Hot Water Flow Connection
R (in BSP/Exl) 1
1
1
1
1 1/4
*Return Connection
Rp (in BSP/Exl) 3/4
3/4
3/4
3/4
3/4
Drain Port Size
R (in BSP/Exl) 3/4
3/4
3/4
3/4
3/4
Max. Working Water Pressure (vented)
bar
10.3
10.3
10.3
10.3
10.3
Max. Working Water Pressure (unvented) bar
5.5
5.5
5.5
5.5
5.5
Water Test Pressure
bar
20.7
20.7
20.7
20.7
20.7
Weight Empty
kg
43
57
65
110
181
Weight Full
kg
151
202
247
396
562
Shipping Weight
kg
44
59
68
120
194
Shipping Dimensions Depth
mm
546
587
587
692
914
Shipping Dimensions Width
mm
486
537
537
651
762
Shipping Dimensions Height
mm
1194
1245
1499
1575
1829
Содержание 24/39
Страница 1: ......
Страница 65: ...Issue 2 14 07 16 65 Parts List and Illustrations 9 9 10 HIflo models 62 341 and 54 418 440 Natural Gas Fig 34 ...
Страница 69: ...Issue 2 14 07 16 69 Parts List and Illustrations 9 9 15 HIflo LPG models L62 309 L54 399 Fig 31 ...
Страница 112: ...112 Issue 2 14 07 16 ...
Страница 113: ...Issue 2 14 07 16 113 ...
Страница 114: ...114 Issue 2 14 07 16 ...