90
Issue 2 14/07/16
10 Appendix
10.4.11 Error code definitions
If the water heater has an operating problem, there will be a
number in the water heater display with “Service Needed”
shown below the error code number. Note the error code and
the definition in the chart below. This label appears on the
control box under the water heater display. The following
sections will provide instructions for servicing each error code.
Honeywell Integrated Control Error Code Display for 24 Volt Damper Models
Error Code
Definition
4
Low flame sense current
55
Damper end switch failed to close (stuck open)
56
Damper end switch failed to open (stuck closed)
6
Flame sensed out of normal sequence (before opening gas valve or after closing gas valve)
23
Flame detected before ignition
24
Flame detected after a heating cycle completes
31
Upper sensor readings faulty
32
Lower sensor readings faulty
57
Flame rod shorted to ground
58
AC line frequency error - signal too noisy or frequency incorrect
59
Line voltage too low or high
61
DC output voltage unstable
62
Maximum number of retries detected
63
Maximum number of ignition recycles detected
64
Electronics Failure
65
High water temperature (over 200°F)
If any of the above codes appear on the control display, contact your plumber or qualified service agent for
service of this water heater.
Содержание 24/39
Страница 1: ......
Страница 65: ...Issue 2 14 07 16 65 Parts List and Illustrations 9 9 10 HIflo models 62 341 and 54 418 440 Natural Gas Fig 34 ...
Страница 69: ...Issue 2 14 07 16 69 Parts List and Illustrations 9 9 15 HIflo LPG models L62 309 L54 399 Fig 31 ...
Страница 112: ...112 Issue 2 14 07 16 ...
Страница 113: ...Issue 2 14 07 16 113 ...
Страница 114: ...114 Issue 2 14 07 16 ...