10.4.3 To change the maximum setpoint limit (max
setpoint) for the temperature setpoint:
Step 1: In service mode press the “Select” button until
“Max Setpoint” is displayed.
Step 2: Press “Set” button to enter setting mode. “Max
Setpoint” will flash to indicate setting mode.
Step 3: Press the “UP” or “DOWN” buttons to change the
maximum setpoint value. This will limit the
maximum setpoint the user can select. Note: The
maximum setpoint is approximately 180°F.
Step 4: Press “Set” button to confirm new “Max Setpoint”
value and stop setting mode.
Fig. 54
Fig. 55
Fig. 56
Fig. 57
“Max setpoint”
flashes
“Max setpoint” continues
to flash while making
adjustments
“Max setpoint”
stops flashing