Firmware Pages and Descriptions
75
NXP-TPI/4 NetLinx Touch Panel Interface
Press and hold the front panel CALIBRATE button to access the Calibration page.
Press the crosshairs to calibrate the panel and return to the last open firmware page.
System Connection Page
The System Connection page (FIG. 57) sets the DNS Address information with its corresponding IP
communication parameters, NetLinx Master communication settings, and reads the device number
assigned to the G4 device.
The elements of the System Connection page are described in the table below:
FIG. 57
System Connection page (showing default values)
System Connection Page Elements
Back:
Saves the changes and returns you to the previously active touch panel page.
Connection Status icon:
This visual display of the connection status allows the user to have a current
update of the TPI/4’s connection status regardless of what page is currently
active.
• A Lock only appears on the icon if the TPI/4 has established a connection with
a currently secured target Master (
requiring a username and password
).
IP Settings:
Sets the IP communication values for the NXP-TPI/4 and contains:
DHCP/Static
Sets the G4 device to either DHCP or Static communication modes.
•
DHCP (Dynamic Host Configuration Protocol)
assigns IP Addresses from
client stations logging onto a TCP/IP network via a DHCP server.
•
Static IP
is a permanent IP Address that is assigned to a node in a TCP/IP
network.
IP Address
Sets the IP Address assigned to the TPI/4.
Subnet Mask
Sets a subnetwork address to the TPI/4.
•
Subnetwork mask
is the technique used by the IP protocol to filter messages
into a particular network segment (Subnet).
Gateway
Sets a gateway value to the TPI/4.
•
Gateway
is a computer that either performs protocol conversion between
different types of networks/applications or acts as a go-between two or more
networks that use the same protocols.
Host Name
Sets the host name of the TPI/4.
IP Settings section
Master Connection section
(NetLinx Master properties)
Master Connection features are not
saved until the panel is rebooted
Red
fields are user-editable
Blue
fields cycle through choices
Grey
fields are read-only
Содержание NetLinx NXP-TPI/4
Страница 38: ...TPI 4 and Panel Interface Setup 32 NXP TPI 4 NetLinx Touch Panel Interface...
Страница 60: ...Upgrading TPI 4 Firmware 54 NXP TPI 4 NetLinx Touch Panel Interface...
Страница 138: ...Troubleshooting 132 NXP TPI 4 NetLinx Touch Panel Interface...
Страница 147: ...Appendix 141 NXP TPI 4 NetLinx Touch Panel Interface...