Configuring Communication
40
NXP-TPI/4 NetLinx Touch Panel Interface
15.
Press the blue
ICSNET/Ethernet
field (
from the Master Connection section
) until the choice cycles
to the word
Ethernet
.
16.
Press the
Mode
field until the choice cycles to the word
URL
.
By selecting
URL
, the System Number field becomes read-only (grey) because the TPI/4
pulls this value directly from the communicating target Master (virtual or not). A virtual
Master system value can be set within the active AMX software applications such as: NetLinx
Studio, TPD4, or IREdit.
17.
Press the
Master IP/URL
field to open a Keyboard and enter the IP Address of the PC used as the
Virtual Master.
18.
Click
Done
to accept the new value and return to the System Connection page.
19.
Do not alter the Master Port Number value (
this is the default value used by NetLinx
).
20.
Press the
Back
button to open the Protected Setup page.
21.
Press the on-screen
Reboot
button to both save any changes and restart the TPI/4.
Master Connection section - NetLinx Master Ethernet IP Address - URL Mode
In this mode, enter the System Number (zero for an unknown System Number) and the IP/URL of the
Master (Master Port Number is defaulted to
1319
).
1.
Press the
ICSNET/Ethernet
field (
from the Master Connection section
) until the choice cycles to
the word
Ethernet
. Refer to the
System Connection Page
section on page 75 for more information
about the fields on this page.
2.
Press the
Mode
field until the choice cycles to the word
URL
.
By selecting
URL
, the System Number field becomes read-only (grey) because the panel pulls
this value directly from the communicating target Master (virtual or not). A virtual Master
system value can be set within the active AMX software applications such as: NetLinx Studio,
TPD4, or IREdit.
3.
Press the
Master IP/URL
field to open a Keyboard and enter the Master IP Address
(obtained from
the Diagnostics - Networking Address dialog
of the NetLinx Studio application)
.
4.
Click
Done
to accept the new value and return to the System Configuration page.
FIG. 26
Sample System Connection page (for Virtual Master communication)
Enter the IP Address
information of the PC
used as a Virtual
Master
The System Number is
assigned to the Virtual
Master within the AMX
software application
(these must match)
If the TPI/4 does not appear within the OnLine Tree tab of the Workspace window of
NetLinx Studio, check to make sure that the NetLinx Master System Number (from
within the Device Addressing dialog) is correctly assigned.
Содержание NetLinx NXP-TPI/4
Страница 38: ...TPI 4 and Panel Interface Setup 32 NXP TPI 4 NetLinx Touch Panel Interface...
Страница 60: ...Upgrading TPI 4 Firmware 54 NXP TPI 4 NetLinx Touch Panel Interface...
Страница 138: ...Troubleshooting 132 NXP TPI 4 NetLinx Touch Panel Interface...
Страница 147: ...Appendix 141 NXP TPI 4 NetLinx Touch Panel Interface...