Configuring Communication
42
NXP-TPI/4 NetLinx Touch Panel Interface
11.
Press the on-screen
Reboot
button to save any changes and restart the TPI/4.
Master Connection section - NetLinx Master Ethernet IP Address - Auto Mode
In this mode, enter the System Number of the NetLinx Master. This mode instructs the TPI/4 to search
for a Master that uses the same System Number (assigned within the Master Connection section)
and
resides on the same Subnet as the TPI/4
.
1.
Toggle the
ICSNET/Ethernet
field until
Ethernet
is selected (
from the Master Connection section of
the System Connection page
).
2.
Press the
Mode
field until the choice cycles to the word
Auto
.
3.
Press the
System Number
field to launch a Keypad and enter the value for the system number of the
NetLinx Master.
This value can be obtained from the NetLinx Studio program > OnLine Tree of the
Workspace window.
4.
Do not alter the IP Settings on the System Connection page, as this field is not applicable to this
connection mode.
5.
Enter a username and password (
into their respective fields
) if the target Master has been previously
secured.
6.
Press the on-screen
Reboot
button to both save any changes and restart the TPI/4.
7.
Press the front panel SETUP button to open the Setup page and confirm there is an active
connection.
Using G4 Web Control to Interact with a G4 Panel
The G4 Web Control feature allows you to use a PC to interact with a G4 enabled device via the web.
This feature works in tandem with the new browser-capable NetLinx Security firmware update
(
build 300 or higher
). G4 Web Control is only available with the latest TPI/4 firmware.
Refer to the
G4 Web Control Page
section on page 99 for more detailed information.
1.
Press the front panel SETUP button to access the Setup page.
2.
Press the
Protected Setup
button (located on the lower-left of the firmware page) to open the
Protected Setup page and display an on-screen keypad.
3.
Enter
1988
into the Keypad’s password field (
1988 is the default password
).
4.
Press
Done
when finished.
5.
Press the
G4 Web Control
button to open the G4 Web Control page (FIG. 28).
6.
Press the
Enable/Enabled
button until it toggles to
Enabled
(
light blue color
).
The NetLinx Master and the TPI/4 must both be on the same Subnet.
Verify your NetLinx Master (ME260/64 or NI-Series) has been installed with the latest
firmware KIT file from
www.amx.com
. Refer to your NetLinx Master Instruction
Manual for more detailed information on the use of the new web-based NetLinx
Security.
Clearing Password #5, from the initial Password Setup page, removes the need for
you to enter the default password before accessing the Protected Setup page.
Содержание NetLinx NXP-TPI/4
Страница 38: ...TPI 4 and Panel Interface Setup 32 NXP TPI 4 NetLinx Touch Panel Interface...
Страница 60: ...Upgrading TPI 4 Firmware 54 NXP TPI 4 NetLinx Touch Panel Interface...
Страница 138: ...Troubleshooting 132 NXP TPI 4 NetLinx Touch Panel Interface...
Страница 147: ...Appendix 141 NXP TPI 4 NetLinx Touch Panel Interface...