Configuring Communication
46
5" Modero Widescreen Touch Panel
Master Connection section - NetLinx Master Ethernet IP Address - Listen Mode
In this mode, you must add the Modero panel IP Address into the URL List of the Master (using NetLinx
Studio). This mode sets the Modero panel to "listen" for broadcasts from the Master (using the panel IP
from its URL list).
1.
Obtain either a Static IP for the Modero panel (from your System Administrator) or a DHCP
Address from the IP Settings of the System Connection page.
The
DHCP/Static
field (in the IP Settings section of the System Connection page) must be set
to
DHCP
to get Dynamic IP information for the panel.
Press the on-screen
Reboot
(from the Protected Setup page) to both save any changes and
restart the panel.
After power-up, press the grey Front Setup Access button for
3 seconds
to access the Setup
page.
Navigate to the
Setup > Protected Setup > System Connection
page and note the newly
obtained Dynamic IP Address information from the IP Settings section. This information is
then entered into the URL List for the connected NetLinx Master.
2.
Toggle the
Type
field until
Ethernet
is selected (
from the Master Connection section of the System
Connection page
).
3.
Press the
Mode
field (to set the connection Mode) until the choice cycles to the word
Listen
.
The
System Number and Master IP/URL fields are then greyed-out.
4.
Enter a username and password (
into their respective fields
) if the target Master has been previously
secured.
5.
Select the
OnLine Tree
tab from the Workspace window.
6.
Select
Diagnostics
>
URL Listing
from the Main menu (FIG. 42).
7.
Enter the
System
and
Device
number for the specific Master associated with your panel (
as seen in
the OnLine Tree tab
).
8.
Click
Add
and enter the IP Address of the Modero touch panel into the
Add URL
dialog.
9.
Click
OK
to enter your IP Address and add it to the list.
10.
Click
Done
once you are finished adding your panel information to the list.
11.
Press the on-screen
Reboot
button to save any changes and restart the panel.
FIG. 42
URL List dialog
System Address
reflects the value
set in the Device
Addressing tab
Used to obtain an
existing URL
Used to set the
URL List
List from Master
on Master
Содержание Modero NXD-CV5
Страница 12: ...Introduction 6 5 Modero Widescreen Touch Panel...
Страница 18: ...CV5 Touch Panel Accessories 12 5 Modero Widescreen Touch Panel...
Страница 58: ...Configuring Communication 52 5 Modero Widescreen Touch Panel...
Страница 98: ...Firmware Pages and Descriptions 92 5 Modero Widescreen Touch Panel...
Страница 158: ...Appendix A 152 5 Modero Widescreen Touch Panel...
Страница 159: ...Appendix A 153 5 Modero Widescreen Touch Panel...
Страница 160: ...Appendix A 154 5 Modero Widescreen Touch Panel...
Страница 161: ...Appendix A 155 5 Modero Widescreen Touch Panels...