Installation Procedures: NXD-1200V Panels
37
NXD/T-1200V Wall/Flush Mount Touch Panel
4.
Thread the incoming RJ-45, Ethernet, USB, and any other audio/video wiring (from their terminal locations)
through the cutout opening. Refer to the
Wiring Guidelines for the 1200V Panels
section on page 41 for pinout
descriptions.
Leave enough slack in the wiring to accommodate any re-positioning of the panel
.
5.
Connect all data and power wiring connectors to their corresponding locations along the side of the (un-powered)
NXD touch panel.
Verify the terminal end of the power cable is not connected to a power supply before plugging in the 2-pin
power connector.
The USB connectors can be from a either a USB extension cable, or a wireless USB RF transmitter.
6.
Test the incoming wiring by attaching the panel connections to their terminal locations and applying power. Verify
the panel is receiving power and functioning properly to prevent repetition of the installation.
7.
Disconnect the terminal end of the power cable from the connected power supply.
8.
Insert the four sets of drywall screws and expansion clips into the four oval notch locations along the top/bottom
edges of the main unit (FIG. 40).
9.
Carefully insert the main unit (with expansion clips) into the cutout until the Mounting Tabs on the NXD unit lie
flush against the wall (FIG. 40).
10.
Tighten the drywall clip sets (screws and clips) until the Mounting Tabs are securely fastened and flush against the
wall.
FIG. 40
Wall Mount panel (NXD) installation configuration for drywall surfaces
B
- Main NXD unit consists of
Install the four drywall
clip sets (included)
into these holes
the touch panel and housing
4 notches are
required if the
unit is installed in
drywall using the
four (4) provided
drywall expansion
A -
Faceplate
(bezel)
clips
Mounting Tab
Don’t disconnect the connectors from the touch panel. The unit must be installed with
the attached connectors before being inserted into the drywall.
The drywall clip set must be re-ordered from AMX if the drywall clip is bent
accidentally during an installation or removed during a re-installation.
Содержание Modero NXD-1200V
Страница 40: ...Touch Panel Accessories 28 NXD T 1200V Wall Flush Mount Touch Panel...
Страница 80: ...Configuring Communication 68 NXD T 1200V Wall Flush Mount Touch Panel...
Страница 92: ...Upgrading Modero Firmware 80 NXD T 1200V Wall Flush Mount Touch Panel...
Страница 164: ...Programming 152 NXD T 1200V Wall Flush Mount Touch Panel...
Страница 170: ...Appendix 158 NXD T 1200V Wall Flush Mount Touch Panel...
Страница 175: ...Troubleshooting 163 NXD T 1200V Wall Flush Mount Touch Panel...