Installation Procedures: NXD-1200V Panels
39
NXD/T-1200V Wall/Flush Mount Touch Panel
4.
Thread the incoming RJ-45, Ethernet, USB, and any other audio/video wiring (from their terminal locations)
through the cutout opening. Refer to the
Wiring Guidelines for the 1200V Panels
section on page 41 for pinout
descriptions.
Leave enough slack in the wiring to accommodate any re-positioning of the panel.
5.
Connect all data and power wiring to their corresponding locations along the side of the
(un-powered) NXD touch panel.
Verify the terminal end of the power cable is not connected to power supply before plugging in the 2-pin
power connector.
The USB connectors can be from a either a USB extension cable, or a wireless USB RF transmitter.
6.
Test the incoming wiring by connecting the panel connections to their terminal locations and applying power. Verify
the panel is receiving power and functioning properly before finalizing the installation.
7.
Disconnect the terminal end of the power cable from the power supply.
8.
Carefully slide the main unit into the cutout until the Mounting Tabs of the NXD unit lie flush against the wall.
9.
Insert and secure the four #4 screws into their corresponding holes located along the sides of the NXD (using a
grounded Phillips-head screwdriver) until the unit is secure and flush against the wall.
10.
Place the magnetic faceplate (
A
in
FIG. 42) back onto the main NXD unit (
B
in
FIG. 42).
Make sure to align the Microphone, Light, and PIR Motion sensor locations to their respective openings on the
front bezel/faceplate.
11.
Reconnect the terminal RJ-45, Ethernet, USB, and any optional audio/video wiring to their respective locations on
either the NXA-AVB/ETHERNET Breakout Box, Ethernet port, or NetLinx Master.
12.
Reconnect the terminal power connector on the 12 VDC-compliant power supply and apply power.
FIG. 42
Wall Mount panel installation configuration for flat/solid surfaces
B
- Main NXD unit consists of
Install the four (#4)
mounting screws
into the holes
(
screws not included
)
Flat surface
(can include a
the touch panel and housing
wall, podium, or
other flat
surface)
A -
Faceplate
(bezel)
Attachment is done
along the edges of
the cutout
Don’t disconnect the connectors from the touch panel. The unit must be installed with
the necessary connectors before being inserted into the solid surface.
Содержание Modero NXD-1200V
Страница 40: ...Touch Panel Accessories 28 NXD T 1200V Wall Flush Mount Touch Panel...
Страница 80: ...Configuring Communication 68 NXD T 1200V Wall Flush Mount Touch Panel...
Страница 92: ...Upgrading Modero Firmware 80 NXD T 1200V Wall Flush Mount Touch Panel...
Страница 164: ...Programming 152 NXD T 1200V Wall Flush Mount Touch Panel...
Страница 170: ...Appendix 158 NXD T 1200V Wall Flush Mount Touch Panel...
Страница 175: ...Troubleshooting 163 NXD T 1200V Wall Flush Mount Touch Panel...