Upgrading Modero Firmware
72
NXD/T-1200V Wall/Flush Mount Touch Panel
8.
Select the panel’s Kit file from the
Files
section.
9.
Enter the
Device
value associated with the panel and the
System
number associated with the Master (
listed
in the
OnLine Tree tab of the Workspace window
).
The Port field is greyed-out.
10.
Click the
Reboot Device
checkbox. This causes the touch panel to reboot after the firmware update process is
complete.
The reboot of the panel can take up 30 seconds after the firmware process has finished.
11.
Click
Send
to begin the transfer. The file transfer progress is indicated on the bottom-right of the dialog (
B
in
FIG. 74).
12.
As the panel is rebooting, temporarily unplug the USB connector on the panel until the panel has completely
restarted.
13.
Reconnect the USB connector to the panel.
14.
Right-click the associated System number and select
Refresh System
. This causes a refresh of all project systems,
establishes a new connection to the Master, and populates the System list with devices on your particular system.
15.
Confirm the panel has been properly updated to the correct firmware version.
Upgrading the Modero Firmware via an IP Address
Before beginning with this section, verify that your panel is powered and connected to the NetLinx Master through an
Ethernet connection (direct or wireless).
Step 1: Prepare the Master for communication via an IP
1.
Obtain the IP Address of the NetLinx Master from your System Administrator. If you do not have an IP Address for
the Master, refer to your particular Master’s instruction manual for more information on obtaining this IP Address
using NetLinx Studio 2.
From the
Online Tree
tab of the Workspace window, select the NetLinx Master.
Follow steps outlined in either the
Obtaining or Assigning the Master’s IP Address
sections from your
particular NetLinx Master instruction manual to use an address.
Note the IP Address and Gateway information.
2.
Launch NetLinx Studio 2.x (default location is
Start
>
Programs
>
AMX Control Disc
>
NetLinx Studio 2
>
NetLinx Studio 2
).
3.
Select
Settings
>
Master Communication Settings
from the Main menu to open the Master Communication
Settings dialog (FIG. 75).
FIG. 74
Using USB for a Virtual Master transfer
A
B
Содержание Modero NXD-1200V
Страница 40: ...Touch Panel Accessories 28 NXD T 1200V Wall Flush Mount Touch Panel...
Страница 80: ...Configuring Communication 68 NXD T 1200V Wall Flush Mount Touch Panel...
Страница 92: ...Upgrading Modero Firmware 80 NXD T 1200V Wall Flush Mount Touch Panel...
Страница 164: ...Programming 152 NXD T 1200V Wall Flush Mount Touch Panel...
Страница 170: ...Appendix 158 NXD T 1200V Wall Flush Mount Touch Panel...
Страница 175: ...Troubleshooting 163 NXD T 1200V Wall Flush Mount Touch Panel...