Upgrading Modero Firmware
71
NXD/T-1200V Wall/Flush Mount Touch Panel
Step 3: Confirm and Upgrade the firmware via the USB port
Use the CC-USB Type-A to Mini-B 5-wire programming cable (
FG10-5965
) to provide communication between the
mini-USB Program port on the touch panel and the PC. This method of communication is used to transfer firmware Kit
files and TPD4 touch panel files.
1.
Verify this direct USB connection (Type-A on the panel to mini-USB on the panel) is configured properly using the
steps outlined in the previous two sections.
2.
With the panel already configured for USB communication and the Virtual Master setup within NetLinx Studio, its
now time to verify the panel is ready to receive files.
3.
After the Communication Verification dialog window verifies active communication between the Virtual Master
and the panel, click the
OnLine Tree
tab in the Workspace window (FIG. 73) to view the devices on the Virtual
System.
The default System value is one
.
4.
Right-click on the System entry (FIG. 73) and select
Refresh System
to re-populate the list. Verify the panel
appears in the
OnLine Tree
tab of the Workspace window.
The default Modero panel value is 10001
.
5.
If the panel firmware being used is not current, download the latest Kit file by first logging in to
www.amx.com
and
then navigate to
Tech Center
>
Firmware Files
and from within the
Modero
section of the web page locate your
Modero panel.
6.
Click on the desired Kit file link and after you’ve accepted the Licensing Agreement, verify you have downloaded
the Modero Kit file to a known location.
7.
From within Studio, select
Tools
>
Firmware Transfers > Send to NetLinx Device
from the Main menu to open
the Send to NetLinx Device dialog (
B
in FIG. 74). Verify the panel’s System and Device number
values match those
values listed within the System folder in the
OnLine Tree
tab of the Workspace window (
A
in FIG. 74).
A mini-USB connection is only detected after it is installed onto an active panel.
Connection to a previously powered panel which then reboots, allows the PC to
detect the panel and assign an appropriate USB driver.
FIG. 73
NetLinx Workspace window (showing panel connection via a Virtual NetLinx Master)
Showing a Master
firmware version and
device number
Showing the current Modero
panel firmware version and
device number
Shows NetLinx Studio
version number
The panel firmware is shown on the right of the listed panel.
Download the latest firmware file from www.amx.com and then save the Kit file to
your computer.
Содержание Modero NXD-1200V
Страница 40: ...Touch Panel Accessories 28 NXD T 1200V Wall Flush Mount Touch Panel...
Страница 80: ...Configuring Communication 68 NXD T 1200V Wall Flush Mount Touch Panel...
Страница 92: ...Upgrading Modero Firmware 80 NXD T 1200V Wall Flush Mount Touch Panel...
Страница 164: ...Programming 152 NXD T 1200V Wall Flush Mount Touch Panel...
Страница 170: ...Appendix 158 NXD T 1200V Wall Flush Mount Touch Panel...
Страница 175: ...Troubleshooting 163 NXD T 1200V Wall Flush Mount Touch Panel...