NetLinx Security with a Terminal Connection
129
NI-3101-SIG Signature Series NetLinx Integrated Controller
Option 12 - Display Telnet Timeout in seconds
This feature is disabled after the installation of firmware build 130 or higher onto your target Master.
1.
Type
12
and <Enter> at the Security Setup prompt (at the bottom of the Main Security Menu) to
view the current Telnet Timeout value (in seconds). A sample session response is:
Telnet Timeout is 10 seconds.
2.
Press <Enter> to return to the Security Setup Menu.
Option 13 - Make changes permanent by saving to flash
When changes are made to the security settings of the Master, they are initially only changed in RAM
and are not automatically saved permanently into flash. This selection saved the current security settings
into flash. Also, if you attempt to exit the Main Security Menu and the security settings have changed but
not made permanent, you will be prompted to save the settings at that time.
Type
13
and <Enter> at the Security Setup prompt to (permanently) save all changes to flash.
Changes made to the target Master from within the Terminal window are not reflected
within the web browser, until the Master is rebooted and the web browser connection
is refreshed.
Any changes made to the Master, from within the web browser are instantly reflected
within the Terminal session without the need to reboot.
Содержание FG2105-08
Страница 12: ...Introduction 6 NI 3101 SIG Signature Series NetLinx Integrated Controller...
Страница 46: ...Configuration and Firmware Update 40 NI 3101 SIG Signature Series NetLinx Integrated Controller...
Страница 142: ...NetLinx Security with a Terminal Connection 136 NI 3101 SIG Signature Series NetLinx Integrated Controller...
Страница 175: ...Troubleshooting 169 NI 3101 SIG Signature Series NetLinx Integrated Controller...