Configuration and Firmware Update
23
NI-3101-SIG Signature Series NetLinx Integrated Controller
7.
Set the COM port parameters for the selected COM port used for communication to the NetLinx
Master. Default parameters are:
COM1
115200
8 Data Bits
No Parity
1 Stop Bit
No Flow Control
If communication fails on a known COM port, change the baud rate to 115200 and try again.
8.
Click
OK
three times to close the open dialogs and save the chosen settings.
Setting the System Value
1.
Access/open the Device Addressing dialog (FIG. 16) by either one of these two methods:
Right-click on any System item listed (such as the NI Master entry) in the
OnLine Tree
tab of
the Workspace and select
Device Addressing (
from the popup list).
Select
Diagnostics
>
Device Addressing
from the Main menu.
No authentication username or password information is required when selecting a
direct connection such as USB or Serial.
If the connection fails to establish, select a different COM port, press the
Retry
button
to reconnect using the same communication parameters, or press the
Change
button
to alter your communication parameters and repeat steps 2 thru 8.
This process should be done while communicating to the Master via a Serial
connection.
FIG. 16
Device Addressing tab (changing the system value)
System Address
(default for initial
system is 1)
Check-Off to
verify change
Содержание FG2105-08
Страница 12: ...Introduction 6 NI 3101 SIG Signature Series NetLinx Integrated Controller...
Страница 46: ...Configuration and Firmware Update 40 NI 3101 SIG Signature Series NetLinx Integrated Controller...
Страница 142: ...NetLinx Security with a Terminal Connection 136 NI 3101 SIG Signature Series NetLinx Integrated Controller...
Страница 175: ...Troubleshooting 169 NI 3101 SIG Signature Series NetLinx Integrated Controller...