Troubleshooting
167
NI-3101-SIG Signature Series NetLinx Integrated Controller
Troubleshooting
This section describes the solutions to possible hardware/firmware issues that could arise during the
common operation of a NetLinx device.
Troubleshooting Information
Symptom
Solution
My NI Controller can’t obtain a
DHCP Address.
In requesting a DHCP Address, the DHCP Server can take up to a few
minutes to provide the address to the on-board Master.
• Verify there is an active Ethernet connection attached to the rear of
the NI-Series Controller before beginning these procedures.
• Select
Diagnostics
>
Network Address
from the Main menu and
verify the System number.
• If the IP Address field is still empty, give the device a few minutes to
negotiate a DHCP Address and try again.
My NI Controller shows the same
IP Address after selecting DHCP
Server and clicking the GET IP
Information button.
In requesting a DHCP Address, the DHCP Server can take up to a few
minutes to provide the address to the on-board Master.
When using a controller that has previously been used, there may be
an instance where the IP Address was set as a fixed IP. In this case,
the address would need to be released so a new user could use a
DHCP server provided address.
• Access the HyperTerminal application and try to communicate to the
controller via the COM port.
• Type
echo on
and press ENTER to send the information to the unit.
• Type
get ip
to display the actual IP Address used by the unit.
• Release the static/fixed IP Addresses.
• Recycle power to the device and retry obtaining a DHCP address
through NetLinx Studio.
My NI Controller still can’t obtain a
DHCP Address even after
completing the above
troubleshooting tip.
If the NI Controller is not connected directly to an open Ethernet wall
connector, but is rather connected to an Ethernet Hub:
• Contact Technical Support for a resolution to issues with this type
of connection scenario.
I can’t detect the NI Controller and
my Status LED is blinking
irregularly.
The on-board Master is trying to establish communication.
• Wait a few moments and retry establishing communication using the
latest NetLinx Studio.
• If the problem persists, cycle power to the unit and repeat the above
procedure. Another solution is to attempt communication via another
method (Configuration Port or IP).
• Refer to the
Configuration and Firmware Update
section on page 21
for more information.
NetLinx Studio only detects one of
my connected Masters.
Each Master is give a Device Address of 00000.
• Only one Master can be assigned to a particular System number. If
you want to work with multiple Masters, open different instances of
NetLinx Studio and assign each Master its own System value.
• Example: A site has an NXC-ME260/64 and an NI-3101-SIG. In order
to work with both units. The ME260/64 can be assigned System #1
and the NI-3101-SIG can then be assigned System #2 using two
open sessions of NetLinx Studio.
Содержание FG2105-08
Страница 12: ...Introduction 6 NI 3101 SIG Signature Series NetLinx Integrated Controller...
Страница 46: ...Configuration and Firmware Update 40 NI 3101 SIG Signature Series NetLinx Integrated Controller...
Страница 142: ...NetLinx Security with a Terminal Connection 136 NI 3101 SIG Signature Series NetLinx Integrated Controller...
Страница 175: ...Troubleshooting 169 NI 3101 SIG Signature Series NetLinx Integrated Controller...