NetLinx Security within the Web Server
99
NI-3101-SIG Signature Series NetLinx Integrated Controller
Manage Other Devices Page (Cont.)
Feature
Description
Configure Binding Options (Cont.):
Enable Subnet Match
This selection allows an end-user to toggle whether or not
IP devices should only be detected/discovered if they are on the
same IP Subnet as the Master.
Purge Bound Modules on Reset
• This selection indicates that all modules should be deleted from
the
/bound
directory upon the next reboot.
• During the binding process, the associated Duet modules for a
device are copied from the
/unbound
directory into a protected
/bound
area.
• Due to the dynamic nature of Java class loading, it is not safe to
delete a running .JAR file. Therefore, this selection provides
the administrator the capability of removing existing modules
upon reboot by forcing a re-acquisition of the module at bind
time.
• This selection is a one-time occurrence. Upon the next
reboot, the selection is cleared.
Save Settings
Clicking this button causes the current selected checkbox values
to be saved into the system.
Enable/Disable Module Search via Internet • Clicking this button toggles the capability of searching the
Internet (
either AMX's site or a device specified site
) for a
device’s compatible Duet modules. This capability is
automatically disabled if the Master does not have Internet
connectivity.
• Upon enabling Internet connectivity, the AMX License
Agreement is displayed for acceptance (FIG. 64). The AMX
License Agreement must be accepted (
by pressing the
Accept
button on the upper-right of the page
) for the Internet Module
search to be enabled.
• When the Internet search for modules feature is enabled (the
button then reads
Disable Module Search via Internet
), the
Master queries either AMX's Online database of device
Modules and/or pulls Modules from a separate site specified by
the manufacturer's device.
• This feature may be disabled later by toggling the button.
Device Configuration Pages:
This section is optional and is only present when either
configuration links have been previously registered by a running
Duet Module, or if a discovered device supplies configuration link
information.
• If present, this section displays each link along with a
mouse-over tool-tip.
• For Duet Modules this tool-tip describes the module
configuration link.
• For discovered devices this tool-tip indicates the physical
device the configuration link is associated with.
Manage Device Modules:
This section displays a list of all currently loaded Duet Modules/
.JAR files on the Master (
resident within the
/unbound
directory
);
as well as providing those interfaces necessary to delete, add,
and retrieve these modules.
Select File to Delete
• This field provides the listing of loaded Modules/.JAR files.
• These entries can be selected for deletion or archiving.
Содержание FG2105-08
Страница 12: ...Introduction 6 NI 3101 SIG Signature Series NetLinx Integrated Controller...
Страница 46: ...Configuration and Firmware Update 40 NI 3101 SIG Signature Series NetLinx Integrated Controller...
Страница 142: ...NetLinx Security with a Terminal Connection 136 NI 3101 SIG Signature Series NetLinx Integrated Controller...
Страница 175: ...Troubleshooting 169 NI 3101 SIG Signature Series NetLinx Integrated Controller...