NetLinx Security within the Web Server
73
NI-3101-SIG Signature Series NetLinx Integrated Controller
5.
Remove a diagnostic filter by clicking the
Modify
button below it (from the Diagnostics dialog),
then pressing the
Remove
button to delete this filter from the Diagnostics dialog.
Once a Preset is assigned to a specific Diagnostic filter "slot" (
up to 8
), its
System
:
Device
:
Port
fields are greyed-out, and can’t be modified unless the Preset in that slot is removed and
replicated with new information within these fields.
To modify a Diagnostic filter’s information (such as System/Device/Port):
Navigate to an empty Diagnostic filter slot and click the
Modify
button below the filter.
Select a previously unused Preset and store it with a new name.
Click the
Remove
button to remove this duplicate Preset from the specific filter slot.
Re-open the empty slot by clicking the
Modify
button, select the duplicated Preset and
click
Recall
.
Change the necessary information (such as the System/Device/Port), then save it as the
original Preset name, and click the
Update
button.
6.
Use the
Incoming Message
field to view all the internal system diagnostic messages that are
generated by a NetLinx Master controller. This message field is a text box, where the text within it
may be selected and then copied or pasted for storage.
Содержание FG2105-08
Страница 12: ...Introduction 6 NI 3101 SIG Signature Series NetLinx Integrated Controller...
Страница 46: ...Configuration and Firmware Update 40 NI 3101 SIG Signature Series NetLinx Integrated Controller...
Страница 142: ...NetLinx Security with a Terminal Connection 136 NI 3101 SIG Signature Series NetLinx Integrated Controller...
Страница 175: ...Troubleshooting 169 NI 3101 SIG Signature Series NetLinx Integrated Controller...