![Amtech Axpert-Eazy AMT-011-4 Скачать руководство пользователя страница 96](http://html1.mh-extra.com/html/amtech/axpert-eazy-amt-011-4/axpert-eazy-amt-011-4_instruction-manual_2937000096.webp)
Amtech
6-50
6
9. FSI 20-0mA
This is an inverse to option-5. When this option is selected, the set torque
M107
corresponds to
analog input FSI. The Maximum 200% torque will be available at 0 mA and minimum 0% at 20 mA.
10. Static potentiometer
When this option is selected, the set torque
M107
will be decided by programmable sequence inputs.
Assign one each programmable sequence input to
Freq Increase
and
Freq Decrease
respectively.
When
Freq Increase
is applied, the set torque will increase and when
Freq Decrease
is applied, the
set torque will decrease. If both the signals are applied simultaneously, it will have no effect.
11. Serial
In this option, the set torque
M107
can be assigned from serial link.
The monitor option M107 will display the corresponding set torque value, even if the AC DRIVE is
stop
12. PID Output
In this option, the PID output will be the set point. When selecting this input, enable the PID Control.
The monitor option M107 will display the corresponding set frequency value, even if the AC DRIVE is
stop.
13. VIN 0-10V
When this option is selected, the set torque
M107
corresponds to analog input VIN. The output torque
will be zero at 0V and maximum at 10V.
A103
0
10V
F
V
A103
0
20mA
F
I
4mA
VIN 0-10V
IIN 4-20mA
14. IIN 4-20mA
When this option is selected, the set torque
M107
corresponds to analog input IIN. The output torque
will be zero at 4mA and maximum at 20mA.
15. PLC A-O/P 1
When this option is selected, the set torque
M107
corresponds to PLC A-O/P 1. This Parameter
option value can be set directly from In-built PLC function. The output torque will be zero at 0d and
maximum at 1000d.
16. PLC A-O/P 2
When this option is selected, the set torque
M107
corresponds to PLC A-O/P 2. This Parameter
option value can be set directly from In-built PLC function. The output torque will be zero at 0d and
maximum at 1000d.
17. PLC A-O/P 3
Содержание Axpert-Eazy AMT-011-4
Страница 2: ...Amtech ii...
Страница 19: ...Axpert Eazy AC Variable Frequency Drive 2 11 2 400V Series AMT 200 4 AMT 250 4...
Страница 22: ...Amtech 2 14 2 This Page is intentionally left blank...
Страница 37: ...Axpert Eazy AC Variable Frequency Drive 4 9 4...
Страница 38: ...Amtech 4 10 4 This page is intentionally left blank...