3. Data Access
3.1 Register Read and Write
The device parameter and data set information is mapped into a 4xxxx register area. This holding
register area can be read from an external device, and an external device can modify the register
values by writing to them.
All parameters have access for either reading or writing. The parameter writes are verified for correct
value, and for valid register addresses. Some parameters never allow writes, some parameters allow
write, and some can be modified at any time.
The register addresses that are not allocated to any device parameter or data set are invalid. No
reads or writes are allowed for these addresses. If there is an attempt to read or write outside the
parameter addresses, the Modbus interface will return an exception code to the controller.
Exception Codes
Below is the table of exception code generated by slave device.
Code Name
Reason
01
ILLEGAL FUNCTION
Unsupported Command.
02
ILLEGAL DATA ADDRESS Address does not exist or is read/write protected.
03
ILLEGAL DATA VALUE
Value is outside min-max limits. Parameter is read-only.
04
SLAVE DEVICE FAILURE
Reading a multiple parameter register, which includes one or
more read protected parameters.
06
SLAVE DEVICE BUSY
Slave device performing other important operation and it
cannot give response. Try with query after sometime.
3.2 Data Update
The device designed for time-optimized, reliable data transfer between the Modbus network and the
master device.
This device supports three function codes of the general modbus protocol. They are as below.
Code
Name
Meaning
03
Read Holding Registers Read the binary contents of holding registers (4X
references) in the slave.
06
Preset Single Register
Presets a value into a single holding register (4X reference).
When broadcast, the function presets the same register
reference in all attached slaves.
16 (10 Hex) Preset Multiple Regs
Presets values into a sequence of holding registers (4X
references). When broadcast, the function presets the same
register references in all attached slaves.
Содержание Axpert-Eazy AMT-011-4
Страница 2: ...Amtech ii...
Страница 19: ...Axpert Eazy AC Variable Frequency Drive 2 11 2 400V Series AMT 200 4 AMT 250 4...
Страница 22: ...Amtech 2 14 2 This Page is intentionally left blank...
Страница 37: ...Axpert Eazy AC Variable Frequency Drive 4 9 4...
Страница 38: ...Amtech 4 10 4 This page is intentionally left blank...
Страница 46: ...Amtech 5 8 5 This page is intentionally left blank...
Страница 216: ...Amtech 13 6 13 This page is intentionally left blank...
Страница 221: ...Axpert Eazy AC Variable Frequency Drive A 5 13 A Outline Dimensions...
Страница 239: ...Notes...
Страница 240: ...Notes...
Страница 241: ......
Страница 242: ...AMTECH...