Axpert-Eazy
AC Variable Frequency Drive
6-39
6
When selected for the normal parameter display in
A601~A608
, the value will be displayed with
“%Tq
” unit.
M210: Excitation Current (%)
The excitation current value is displayed using the motor rated current
B103
as 100%. When the AC
DRIVE is stop, it will display zero.
When selected for the normal parameter display in
A601~A608
, the value will be displayed with
“%Ex
” unit.
M211: Heat Sink Temperature (°F)
This parameter displays the actual heat sink temperature in
°F
. When selected for the normal
parameter display in
A601~A608
, the value will be displayed with “
°F
” unit.
M212: Energy Saved in kWH
M213: Energy Saved in MWH
This parameter displays the total power saved per hour basis using VFD. This may differ from the
actually saved energy. To get the nearest value, enter the kW consumption in
B112
before the VFD is
installed. The energy saved is stored in the non-volatile memory.
M214: Hank Count
This parameter displays the current hank count. The max possible value is 6553.5. It is cleared to
zero when power is turned off.
M215: Money Saved with VFD
M216: Money Saved with VFD x1K
This parameter displays the money saved using VFD. This may differ from the actually saved money.
To get the nearest value, enter the kW consumption in
B112
before the VFD is installed. Also, enter
the energy cost in parameter
B114
and select your currency unit in parameter
B113
. Parameter
M216
shows the money saved in x1000.
M217: Encoder Count
This parameter displays the Encoder count as per below formula,
Encoder Count = (Encoder Pulses (B109) * Motor Speed (M102)* 4 *Speed loop time (B601)) /
(60*1000).
M218: ASR O/P Monitor
The ASR output is displayed. The polarity is positive during forward run drive, negative during forward
run regeneration, negative during reverse run drive, and positive during reverse run regeneration. This
is displayed as a percentage in respect to the motor's rated torque.
When selected for the normal parameter display in
A601~A608
, the value will be displayed with
“ASR
” unit.
M219: ACR O/P Monitor
The ACR output is displayed. The polarity is positive during forward run drive, negative during forward
run regeneration, negative during reverse run drive, and positive during reverse run regeneration.
When selected for the normal parameter display in
A601~A608
, the value will be displayed with
“ACR
” unit.
Содержание Axpert-Eazy AMT-011-4
Страница 2: ...Amtech ii...
Страница 19: ...Axpert Eazy AC Variable Frequency Drive 2 11 2 400V Series AMT 200 4 AMT 250 4...
Страница 22: ...Amtech 2 14 2 This Page is intentionally left blank...
Страница 37: ...Axpert Eazy AC Variable Frequency Drive 4 9 4...
Страница 38: ...Amtech 4 10 4 This page is intentionally left blank...
Страница 46: ...Amtech 5 8 5 This page is intentionally left blank...
Страница 216: ...Amtech 13 6 13 This page is intentionally left blank...
Страница 221: ...Axpert Eazy AC Variable Frequency Drive A 5 13 A Outline Dimensions...
Страница 239: ...Notes...
Страница 240: ...Notes...
Страница 241: ......
Страница 242: ...AMTECH...